LG UV18H.NJ1/UU18WH.UE1 5kw 18,000btu Heat Pump H Inverter Ceiling Suspended System

The LG CEILING SUSPENDED range comes with airflow direction control, precise temperature reading and the option of a wired remote controller.





Click to enquire

 

 

 

 

 

 

 

Model Indoor Unit UV18H.NJ1
   
Cooling Capacity Min~Rated~Max kW 2.00~5.00~5.50
Heating Capacity Min~Rated~Max kW 2.20~5.40~6.10
Power Input Cooling (Rated~Max) kW 1.31 ~ 1.87
Heating (Rated~Max) kW 1.49 ~ 2.20
EER W/W 3.82
COP W/W 3.62
SEER 5.21
SCOP 3.81
PdesignH (@-10°C) kW 5.3
Energy Label Cooling/Heating A/A
Annual Energy Consumption Cooling/Heating kWh 337 / 1,953
Power Supply Ø / V / Hz 1 / 220-240 / 50
Air Flow Rate Indoor, H/M/L m3/min 13.9 / 12.9 / 11.9
Sound Pressure Level Indoor, H/M/L dB(A)±3 45 / 43 / 41
Operation Range Cooling (Indoor) °C 18~30
Cooling (Outdoor) °C -10~48
Heating (Indoor) °C 16~30
Heating (Outdoor) °C -18~18
Running Current Cooling/Heating A 0.6 / 0.6
Power Supply to... Outdoor
Moisture Removal Rate l/h 1.6
Drain Hose (O.D / I.D.) mm 20 / 16
Dimensions Indoor (WxHxD) mm 950x650x220
Net Weight Indoor kg 24.6
   
Model Outdoor Unit UU18WH.UE1
   
Power Supply Ø / V / Hz 1 / 220-240 / 50
Running Current Cooling/Heating A 6.0 / 6.7
Starting Current Cooling/Heating A < 6.0 / 6.7
Suggested Circuit Breaker Type C A 16
Power Supply to... Outdoor
Interconnecting Cable 3-Core + Earth
Compressor Type Twin Rotary
Air Flow Rate Outdoor, Max m3/min 58
Sound Level Cooling/Heating dB(A)±3 47 / 50
Night Operation dB(A)±3 39
Dimensions Outdoor (WxHxD) mm 870x808x320
Net Weight Outdoor kg 58
Refrigerant & Charge R410A g 2000
Additional Refrigerant charge g/m 20 (>10.0m)
Piping Connections Liquid Side mm (in) 6.35 (1/4)
Gas Side mm (in) 12.7 (1/2)
Piping Length (Min/Max) m (5/50)
Max. Elevation Difference m 20