LG UV21H.NK1/UU21WH.U41 6kw 21,000btu Heat Pump H Inverter Ceiling Suspended System

The LG CEILING SUSPENDED range comes with airflow direction control, precise temperature reading and the option of a wired remote controller.





Click to enquire

 

 

 

 

 

 

 

Model Indoor Unit UV21H.NK1
   
Cooling Capacity Min~Rated~Max kW 2.80~6.00~8.00
Heating Capacity Min~Rated~Max kW 3.10~7.00~9.00
Power Input Cooling (Rated~Max) kW 1.60 ~ 2.64
Heating (Rated~Max) kW 1.66 ~ 2.80
EER W/W 3.75
COP W/W 4.22
SEER 5.31
SCOP 4.01
PdesignH (@-10°C) kW 7
Energy Label Cooling/Heating A / A+
Annual Energy Consumption Cooling/Heating kWh 396 / 2,450
Power Supply Ø / V / Hz 1 / 220-240 / 50
Air Flow Rate Indoor, H/M/L m3/min 20.4 / 18.8 / 17.2
Sound Pressure Level Indoor, H/M/L dB(A)±3 44 / 42 / 41
Operation Range Cooling (Indoor) °C 18~30
Cooling (Outdoor) °C -10~48
Heating (Indoor) °C 16~30
Heating (Outdoor) °C -18~18
Running Current Cooling/Heating A 0.7
Power Supply to... Outdoor
Moisture Removal Rate l/h 1.9
Drain Hose (O.D / I.D.) mm 20 / 16
Dimensions Indoor (WxHxD) mm 1350x650x220
Net Weight Indoor kg 35
   
Model Outdoor Unit UU21WH.U41
   
Power Supply Ø / V / Hz 1 / 220-240 / 50
Running Current Cooling/Heating A 7.6 / 7.7
Starting Current Cooling/Heating A < 7.6 / 7.7
Suggested Circuit Breaker Type C A 16
Power Supply to... Outdoor
Interconnecting Cable 3-Core + Earth
Compressor Type Twin Rotary
Air Flow Rate Outdoor, Max m3/min 58
Sound Level Cooling/Heating dB(A)±3 47 / 50
Night Operation dB(A)±3 44
Dimensions Outdoor (WxHxD) mm 950x834x330
Net Weight Outdoor kg 63
Refrigerant & Charge R410A g 2200
Additional Refrigerant charge g/m 40 (>10.0m)
Piping Connections Liquid Side mm (in) 9.52 (3/8)
Gas Side mm (in) 15.88 (5/8)
Piping Length (Min/Max) m (5/30)
Max. Elevation Difference m 30