LG UV36H.NL1/UU37WH.U31 10kw 36,000btu Heat Pump H Inverter Ceiling Suspended System (3 Phase)
The LG CEILING SUSPENDED range comes with airflow direction control, precise temperature reading and the option of a wired remote controller.
Model Indoor Unit | UV36H.NL1 |
Cooling Capacity Min~Rated~Max kW | 4.30~10.00~12.40 |
Heating Capacity Min~Rated~Max kW | 4.20~10.50~13.70 |
Power Input Cooling (Rated~Max) kW | 2.77 ~ 4.16 |
Heating (Rated~Max) kW | 2.62 ~ 4.70 |
EER W/W | 3.61 |
COP W/W | 4.01 |
SEER | 5.61 |
SCOP | 4.11 |
PdesignH (@-10°C) kW | 11.3 |
Energy Label Cooling/Heating | A+ / A+ |
Annual Energy Consumption Cooling/Heating kWh | 1385 |
Power Supply Ø / V / Hz | 1 / 220-240 / 50 |
Air Flow Rate Indoor, H/M/L m3/min | 28.6 / 26.9 / 25.2 |
Sound Pressure Level Indoor, H/M/L dB(A)±3 | 46 / 44 / 43 |
Operation Range Cooling (Indoor) °C | 18~30 |
Cooling (Outdoor) °C | -10~48 |
Heating (Indoor) °C | 16~30 |
Heating (Outdoor) °C | -18~18 |
Running Current Cooling/Heating A | 0.90 / 0.90 |
Power Supply to... | Outdoor |
Moisture Removal Rate l/h | 2.93 |
Drain Hose (O.D / I.D.) mm | 20 / 16 |
Dimensions Indoor (WxHxD) mm | 1750×650×220 |
Net Weight Indoor kg | 45 |
Model Outdoor Unit | UU37WH.U31 |
Power Supply Ø / V / Hz | 1 / 220-240 / 50 |
Running Current Cooling/Heating A | 11.5 / 11.3 |
Starting Current Cooling/Heating A | < 11.5 / 11.3 |
Suggested Circuit Breaker Type C A | 25 |
Power Supply to... | Outdoor |
Interconnecting Cable | 3-Core + Earth |
Compressor Type | Twin Rotary |
Air Flow Rate Outdoor, Max m3/min | 55 x2 |
Sound Level Cooling/Heating dB(A)±3 | 51 / 53 |
Night Operation dB(A)±3 | 47 |
Dimensions Outdoor (WxHxD) mm | 950x1380x330 |
Net Weight Outdoor kg | 103 |
Refrigerant & Charge R410A g | 3600 |
Additional Refrigerant charge g/m | 40 (>7.5m) |
Piping Connections Liquid Side mm (in) | 9.52 (3/8) |
Gas Side mm (in) | 15.88 (5/8) |
Piping Length (Min/Max) m | (5/75) |
Max. Elevation Difference m | 30 |